MILWAUKEE ELECTRIC TOOL CORPORATION
13135 WEST LISBON ROAD • BROOKFIELD, WISCONSIN 53005 USA
(262) 781-3600
TO: AUTHORIZED portable electric tool SERVICE STATIONS DATE: January 2008
factory SERVICE / SALES SUPPORT BRANCH
TOOL(S) \ PRODUCT(S) AFFECTED: 2601-20 18.0V Li-Ion Compact Driver/Drill
48-11-1815 18.0V 1.4Ahr Li-Ion Battery Pack, 48-59-1801 18.0V Charger
SUBJECT: Troubleshooting Guide 48-59-1801 18.0V Charger / 48-11-1815 18.0V Li-Ion Battery Pack
Symptom
Possible Cause(s) Solution(s)
Battery Pack
connected to
Charger, RED
or GREEN
LED lights
failure to turn
“on”.
Line voltage too high or too
low (or no power present)
Charger temperature too high
>212ºF
(100ºC)
Faulty Battery Pack – ‘blown’
FET
Faulty Charger
Remove Battery Pack. Unplug Charger and verify correct line voltage -
90VAC – 132VAC for 120VAC Charger
Allow Charger to cool 3-5 minutes before attempting charge. Power must be
removed for a minimum of one minute then reapplied if this condition occurs.
Try known good Battery Pack on the questionable Charger, or try questionable
Battery Pack on known good Charger. FET can fail when battery pack is
repeatedly over-loaded - under extreme circumstances, the internal
temperature of the battery becomes too high or subjected to water.
UNPLUG Charger - high voltage is present at the AC High Voltage Heat Sink -
when AC line voltage is applied to the Charger circuit board. Check for ‘blown’
Charger DC low voltage ‘one-time’ output protection fuse F2 with Volt-Ohm
Meter and/or ‘blown’ Charger AC line fuse - F1, if fuse F2 checks OK. NOTE:
Before checking fuses F1 or F2 unplug the Charger from power source and let
it sit for 3-4 minutes before disassembling – this allows circuit board capacitor
to self discharge.
Use only a battery operated VOM to perform FUSE continuity test – it may be
necessary to pierce / scrap the protective coating of PCB board on end of fuse
to obtain valid continuity reading.
48-59-1801 Charger has no serviceable replacement
parts.
T
O INFORM YOU
PRODUCT
SUPPORT
BULLETIN # 474
AC HIGH VOLTAGE HEAT SINK
DC HEAT SINK SIDE
F1
FUSE
F2
FUSE
Vue de la page 0
1 2

Résumé du contenu

Page 1 - O INFORM YOU

MILWAUKEE ELECTRIC TOOL CORPORATION 13135 WEST LISBON ROAD • BROOKFIELD, WISCONSIN 53005 USA (262) 781-3600 TO: AUTHORIZED portable e

Page 2

Symptom Possible Cause(s) Solution(s) Battery Pack fuel gauge LEDs fail to progress from 1 to 2 to 3 to 4 LED lit first LED only, stays blinking